Type 2 General Purpose Stainless Steel Cavity Wall Ties
The unique tangle free design of the Type 2 General Purpose Tie offers a practical and cost effective solution for masonry cavity walls in domestic houses and small commercial buildings of up to three storeys or a maximum 15m in height.
Fully tested to BS EN 846-5: 2012 the ties meet the requirements of BS EN 845-1: 2013. They will also meet the requirements of Part E of the Building Regulations for Type B in external walls.
All type 2 cavity wall ties are independently tested at Lucideon, a notified body number 1289, to comply with BS EN 845-1:2013.
UNIQUE DESIGN ADVANTAGES
- Tangle Free
- Supplied in bundles – practical benefits for the bricklayer
- Safety on site
- No Boxes – No packaging waste
- Better Storage particularly during inclement weather
TECHNICAL INFORMATION
SIZE | CAVITY WIDTH | PRODUCT CODE |
200mm | 50mm to 75mm | DD2 200 |
225mm | 76mm to 100mm | DD2 225 |
250mm | 101mm to 125mm | DD2 250 |
300mm | 101mm to 125mm | DD2 300 |
275mm | 126mm to 150mm | DD2 275 |
300mm | 126mm to 150mm | DD2 300 |
CLASSIFICATION | FIELD OF USETYPE OF STRUCTURE AND FREQUENCY OF TYING |
GEOGRAPHICAL LOCATION |
Type 2. (Masonry: General purpose). |
Suitable for masonry cavity walls of domestic houses and small,commercial buildings of up to three storeys, i.e. not greater than 15m,in height, comprising two leaves of brick or blockwork of similar,thickness in the range 90mm to 150mm. May be suitable for cavity walls,having leaves of disperate thickness or stiffness or for cladding walls,in high rise buildings, but should only be used in these situations if,shown to be of adequate performance by calculation. Density not less,than 2.5 ties per square metre. | Flat sites where the,basic wind speed is,up to 31m/s at an,altitude no more than,150m above sea level. |
LOOK FOR
THE LABEL
TT2 ties are
coded blue